Besides monitoring and controlling products locally on the CCGX itself, all readings are also forwarded to our free remote monitoring website: the VRM Online Portal. To get an impression, try the demo on https://vrm.victronenergy.com. See also the screenshots below.
Monitor, control and configure the CCGX remotely, over the internet. Just like standing in front of the device, everything can also be done remotely. The same functionality is also available on the local network, Remote Console on LAN.
A highly customizable start/stop system. Use state of charge, voltage, load and other parameters. Define a special set of rules for quiet times, and optionally a monthly test run.
The CCGX is the Energy Manager in an ESS system. More information in the ESS manual
When connected to the internet, all data is sent to the VRM Portal. When there is no internet connection available, the CCGX will store the data internally, up to 48 hours. By inserting a micro SD card or USB stick, more data can be stored. These files can then be uploaded to the VRM Portal, o offline converted with the VictronConnect app, for analysis.
Weight | 0.25kg |
---|---|
Dimensions | 13cm · 12cm · 2.8cm |
Product Title | Victron Energy Color Control GX Retail |
Stock Code | VBPP010300100R |
Product Code | BPP010300100R |
Power supply voltage range | 8 – 70V DC |
Current draw 12V DC | 140mA/160mA/245mA (Display off/Display at minimum intensity/Display at maximum intensity) |
Current draw 24V DC | 80mA/90mA/125mA (Display off/Display at minimum intensity/Display at maximum intensity) |
Current draw 48V DC | 40mA/45mA/65mA(Display off/Display at minimum intensity/Display at maximum intensity) |
Potential free contact | 3A / 30V DC / 250V AC (Normally open) |
VE.Direct | 2 separate VE.Direct ports – isolated |
VE.Can | 2 paralleled RJ45 sockets – isolated |
VE.Bus | 2 paralleled RJ45 sockets – isolated |
USB | 2 USB Host ports – not isolated |
Ethernet | 10/100/1000MB RJ45 socket – isolated except shield |
Modbus-TCP | Use Modbus-TCP to monitor and control all products connected to the Color Control GX |
JSON | Use the VRM JSON API to retrieve data from the VRM Portal |
Operating temperature range | -20 to +50°C |