The wireless solution to set up, monitor, update and synchronise SmartSolar Charge Controllers.
For a wired data connection to a Color Control GX, other GX products, PC or other devices
Especially in the case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30 % compared to PWM charge controllers and by up to 10 % compared to slower MPPT controllers.
If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP. The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
No cooling fan. Maximum efficiency exceeds 98 %. Full output current up to 40 °C (104 °F).
Fully programmable charge algorithm (see the software page on our website), and eight preprogrammed algorithms, selectable with a rotary switch (see manual for details).
- Over-temperature protection and power derating when the temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
Compensates absorption and float charge voltage for temperature.
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers.
Will initiate charging even if the battery has been discharged to zero volts. Will reconnect to a fully discharged Li-ion battery with an integrated disconnect function.
Weight | 1.25kg |
---|---|
Dimensions | 13cm · 18.6cm · 7cm |
Product Title | Victron Energy SmartSolar MPPT 150/45-Tr Solar Charge Controller |
Stock Code | VSCC115045211 |
Product Code | SCC115045211 |
Battery voltage | 12 / 24 / 48 V Auto Select (software tool needed to select 36 V) |
Rated charge current | 45A |
Nominal PV power 1a, b) | 35 A 12 V: 500 W / 24 V: 1000 W / 36 V: 1500 W / 48 V: 2000 W |
Max. PV short circuit current | 50A |
Maximum PV open circuit voltage | 150 V absolute maximum coldest conditions 145 V start-up and operating maximum |
Maximum efficiency | 98% |
Self-consumption | 12 V: 20 mA 24 V: 15 mA 48 V: 10 mA |
Charge voltage 'absorption' | Default setting: 14,4 / 28,8 / 43,2 / 57,6 V (adjustable) |
Charge voltage 'float' | Default setting: 13,8 / 27,6 / 41,4 / 55,2 V (adjustable) |
Charge algorithm | multi-stage adaptive (eight pre-programmed algorithms) |
Temperature compensation | -16 mV / -32 mV / -64 mV / °C |
Protection | PV reverse polarity / output short circuit / over-temperature |
Operating temperature | -30 to +60°C (full rated output up to 40°C) |
Humidity | 95 %, non-condensing |
Data communication port | VE.Direct |
Colour | Blue (RAL 5012) |
Power terminals | 16 mm² / AWG6 |
Protection category | IP43 (electronic components), IP22 (connection area) |
Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 |
Data stored | Battery voltage,current and temperature, as well as load output current, PV voltage and PV current. |
Number of days trends data is stored | 46 |