Especially in the case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP. The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
No cooling fan. Maximum efficiency exceeds 98%. The full output current up to 40°C (104°F).
Fully programmable charge algorithm (see the software page on our website), and eight pre-programmed algorithms, selectable with a rotary switch (see manual for details).
Over-temperature protection and power derating when the temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
Compensates absorption and float charge voltage for temperature.
Up to 25 units can be synchronised with VE.Can
For a wired data connection to a Color Control GX, other GX products, PC or other devices
To connect for example to a VE.BUS BMS.
Can be programmed to trip on an alarm or other events.
Simply remove the rubber seal that protects the plug on the front of the controller, and plug in the display.
Weight | 4.5kg |
---|---|
Dimensions | 21.6cm · 29.5cm · 10.3cm |
Product Title | Victron Energy BlueSolar MPPT 250/100-Tr VE.Can Solar Charge Controller |
Stock Code | VSCC125110441 |
Product Code | SCC125110441 |
Battery voltage | 12 / 24 / 48 V Auto Select (software tool needed to select 36 V) |
Rated charge current | 100A |
Nominal PV power, 12V | 1450 Watts |
Nominal PV power, 24V | 2900 Watts |
Nominal PV power, 36V | 4350 Watts |
Nominal PV power, 48V | 5800 Watts |
Max. PV short circuit current | 70A |
Maximum PV open circuit voltage | 150V resp. 250V absolute maximum coldest conditions 145V resp. 245V start-up and operating maximum |
Maximum efficiency | 99% |
Self-consumption | Less than 35mA @ 12V / 20mA @ 48V |
Charge voltage 'absorption' | Default setting: 14,4 / 28,8 / 43,2 / 57,6V (adjustable with: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'float' | Default setting: 13.8 / 27.6 / 41.4 / 55.2V (adjustable: rotary switch, display, VE.Direct or Bluetooth) |
Charge voltage 'equalization' | Default setting: 16.2V / 32.4V / 48.6V / 64.8V (adjustable) |
Charge algorithm | multi-stage adaptive (eight preprogrammed algorithms) or user defined algorithm |
Temperature compensation | -16 mV / -32 mV / -64 mV / °C |
Protection | PV reverse polarity / Output short circuit / Over temperature |
Operating temperature | -30 to +60°C (full rated output up to 40°C) |
Humidity | 95 %, non-condensing |
Maximum altitude | 5000m (full rated output up to 2000m) |
Environmental condition | Indoor, unconditioned |
Pollution degree | PD3 |
Data communication port | VE.Direct and VE.Can |
Remote on/off | Yes (2 pole connector) |
Programmable relay | DPST AC rating: 240VAC / 4A DC rating: 4A up to 35VDC, 1A up to 60VDC |
Parallel operation | Yes, parallel synchronised operation with VE.Can (max. 25 units) |
Colour | Blue (RAL 5012) |
PV terminals | 35 mm² / AWG2 |
Battery terminals | 35mm² / AWG2 |
Protection category | IP43 (electronic components), IP22 (connection area) |
Safety | EN/IEC 62109-1, UL 1741, CSA C22.2 |